In a fuel cell system, reliability does not depend solely on the stack. Balance-of-plant components play an essential role in system performance, durability and availability.
Recirculation blowers, ejectors, valves, water separators and heat exchangers are exposed to particularly demanding operating conditions.
Variable temperatures, high humidity, condensate, pressure cycles, cold starts and rapid load variations can all contribute to component degradation.
How can these phenomena be identified before they lead to failures under real operating conditions?
This is precisely the purpose of accelerated reliability and robustness testing.
What Is HALT Testing?
HALT, or Highly Accelerated Limit Testing, is a method used to identify design limits and potential failure modes.
Unlike conventional qualification tests, the objective is not simply to verify that a component meets its specifications.
Instead, HALT testing aims to identify its operating limits by progressively increasing the applied stresses.
In its conventional form, HALT combines thermal and vibration stresses. These methods are notably described in standard IEC 62506:2023, which covers accelerated testing methods.
A failure detected during testing provides valuable information for understanding a design weakness.
However, this approach must be distinguished from quantitative lifetime testing. HALT testing alone cannot predict how many years a piece of equipment will operate.
Why Do Hydrogen Components Require Specific Testing?
Components in an anode recirculation loop operate in a particularly complex environment.
A recirculation system may be exposed simultaneously to variations in flow rate, pressure, gas composition, temperature and humidity.
These physical phenomena are strongly interconnected.
A change in temperature can lead to condensation. Water accumulation can disrupt blower or ejector operation. Start-up cycles can also place stress on motors, bearings, seals and control components.
Testing each of these phenomena separately is not always sufficient to reproduce the conditions encountered in a real system.
The challenge is therefore to perform tests under combined stresses, in an environment representative of the component's actual operating conditions.
Accelerated Aging, Endurance and Limit Testing: What Are the Differences?
These three approaches address complementary objectives.
Endurance Testing
Endurance testing involves operating a component continuously over an extended period or repeating a large number of cycles.
It can be used to monitor performance drift, power consumption, flow rate variations and intermittent faults.
Accelerated Aging Testing
Accelerated aging tests use selected stresses to promote the occurrence of degradation mechanisms.
For hydrogen components, these may include thermal stresses, humidity, frequent cycling or repeated variations in operating conditions.
However, quantitative lifetime extrapolation requires appropriate acceleration models and supporting data.
HALT-Inspired Operating Limit Testing
This approach aims to identify the operating range and the mechanisms that may lead to failure.
Stresses are progressively increased according to a defined test protocol, while the component is monitored using instrumentation.
This helps identify the most critical parameters and guide design improvements.
How Can Real Anode Recirculation Conditions Be Reproduced?
To address these challenges, GEMESIS has developed the GMS TS001, a test platform designed for testing anode recirculation components used in fuel cell systems.
Its key feature is the ability to reproduce a closed-loop recirculation system rather than a simple single-pass gas flow.
The test bench combines several complementary testing capabilities:
- A climate chamber operating from -25 to +85°C
- Hydrogen supply up to 9 kg/h at 12 bar absolute
- Steam humidification up to 21 kg/h and liquid water injection up to 300 mL/min
- Independent thermal control circuits
- Electrical power supplies and CAN, PWM and analog control interfaces
- Data acquisition down to 1 ms on selected channels
These capabilities make it possible to reproduce a wide range of operating conditions encountered in real systems.
What Reliability Tests Can Be Performed on the GMS TS 001?
Recirculation Blowers and Compressors
Testing can focus on performance evolution, start-up cycles, cold operation, condensation phenomena and electrical power consumption monitoring.
Acoustic or vibration instrumentation can also be added to monitor operating signatures.
Ejectors and Jet Pumps
Test campaigns can investigate entrainment performance and sensitivity to pressure conditions, flow rates and gas composition.
Valves and Control Components
Testing can focus on response times, hysteresis, repeatability, pressure losses and performance drift after repeated cycling.
Water Separators and Anode Modules
The test bench can be used to investigate droplet carryover, water accumulation, condensation and interactions between components.
For complete assemblies, it is also possible to evaluate start-up and shutdown sequences and purge strategies.
Can a Conventional HALT Test Be Performed on the GMS TS 001?
The GMS TS001 supports accelerated testing under thermal, fluidic and electrical stresses, as well as operating limit investigation campaigns.
However, its current configuration does not include a multi-axis vibration system.
It should therefore not be presented as a complete conventional HALT chamber.
Its main advantage lies in its ability to investigate stresses directly related to the physical phenomena affecting hydrogen components.
For each test campaign, the facility's operating limits, the representativeness of the applied stresses and safety requirements must be taken into account.
Towards a Better Understanding of Hydrogen System Reliability
Component reliability cannot be assessed solely by its ability to operate at a nominal operating point.
It also depends on how it responds to extreme conditions, transient events, repeated stresses and interactions with other system components.
Accelerated testing helps identify potential weaknesses earlier and provides data to support technical decisions.
With the GMS TS001, GEMESIS provides hydrogen component manufacturers with an instrumented test platform, controlled by GEMS software and operated directly at GEMESIS facilities.
Are You Developing a Blower, Ejector, Valve or Anode Module?